| Model | LAQUA PC210
pH/ORP/Cond/TDS/Res/Sal/Temp (°C/°F) |
|---|---|
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 (USA & NIST), Up to 6 (DIN) |
| Buffer Options | USA, NIST, DIN |
| ORP Range | ± 2000 mV |
| Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
| Accuracy | ± 0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
| Calibration Option | Yes |
| Conductivity Range | …µS/cm to 200.0 mS/cm (k=1.0) |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
| Reference Temperature | 15 to 30 °C (adjustable) |
| Temperature Coefficient | 0.00 to 10.00% (adjustable) |
| Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
| Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
| Unit Setting | S/cm, S/m (Auto-ranging) |
| TDS Range | …ppm to 100 ppt (TDS factor=0.5) |
| Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
| Accuracy | ±0.1% full scale |
| Calibration Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
| Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
| Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
| Resolution | 0.1 ppt / 0.01 % |
| Accuracy | ±0.2% full scale |
| Calibration Curves | NaCl, Seawater |
| Calibration Option | Yes |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Calibration Option | Yes |
| Memory Data | 500 |
| Auto Log Data | Yes |
| Measurement Modes | Auto Stable, Auto Hold, Real Time |
| Offset / Average Slope Display | Yes |
| Calibration Alarm | Yes (Programmable: up to 90 days) |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| Meter Inputs | 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
LAQUA PC210
Handheld Water Quality Meters
Package Details:
- LAQUA PC210 dual channel pH/ORP/Cond/TDS/Res/Sal/Temp meter
- 2 x AA batteries
- Manual and quick guide
- 9652-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
- 9383-10D plastic-body, Ti/Pt black, conductivity probe (k=1.0) with integrated temperature sensor
- pH 4.01 and 7.00 buffers, 1413µS/cm and 12.88 mS/cm conductivity solutions (60ml each)
- Electrode adapter
- Carrying case
PC210-KN: Kit with pH 4.01 and 6.86 NIST buffers (60ml each) is available upon request.